On the demo go
Welcome !\Chart styles\Standard\Bar\Bar Size example
Double click the yellow bit to get the editor and click Series tab, the following results
System.ArgumentOutOfRangeException: Index was out of range. Must be non-negative and less than the size of the collection.
Parameter name: index
at System.ThrowHelper.ThrowArgumentOutOfRangeException(ExceptionArgument argument, ExceptionResource resource)
at System.ThrowHelper.ThrowArgumentOutOfRangeException()
at Steema.TeeChart.Editors.SeriesEditor.ShowSeriesForm(Int32 index)
at Steema.TeeChart.Editors.SeriesEditor.SetSeries(Series s, Control parent)
at Steema.TeeChart.Editors.SeriesEditor..ctor(Series s, Control parent)
at Steema.TeeChart.Editors.ChartEditor.CBSeries_SelectedIndexChanged(Object sender, EventArgs e)
at System.Windows.Forms.ComboBox.OnSelectedIndexChanged(EventArgs e)
at System.Windows.Forms.ComboBox.set_SelectedIndex(Int32 value)
at Steema.TeeChart.Editors.ChartEditor.tabControl1_SelectedIndexChanged(Object sender, EventArgs e)
at System.Windows.Forms.TabControl.OnSelectedIndexChanged(EventArgs e)
at System.Windows.Forms.TabControl.WmSelChange()
at System.Windows.Forms.TabControl.WndProc(Message& m)
at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)
at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)
at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
bug in demo Bar Size example V3.2.289.29191
-
- Site Admin
- Posts: 14730
- Joined: Mon Jun 09, 2003 4:00 am
- Location: Banyoles, Catalonia
- Contact:
Hi Adrian,
This is because BarSize series is a custom series derived from Bar series and doesn't have any editor associated. To solve this issue you can use RegisterSeries method as I showed in one of the examples here.
This is because BarSize series is a custom series derived from Bar series and doesn't have any editor associated. To solve this issue you can use RegisterSeries method as I showed in one of the examples here.
Best Regards,
Narcís Calvet / Development & Support Steema Software Avinguda Montilivi 33, 17003 Girona, Catalonia Tel: 34 972 218 797 http://www.steema.com |
Instructions - How to post in this forum |
-
- Site Admin
- Posts: 14730
- Joined: Mon Jun 09, 2003 4:00 am
- Location: Banyoles, Catalonia
- Contact:
Hello Adrian,
Ok, I'll add your request to the wish-list to be considered for inclusion in future releases.
Ok, I'll add your request to the wish-list to be considered for inclusion in future releases.
Best Regards,
Narcís Calvet / Development & Support Steema Software Avinguda Montilivi 33, 17003 Girona, Catalonia Tel: 34 972 218 797 http://www.steema.com |
Instructions - How to post in this forum |
-
- Site Admin
- Posts: 14730
- Joined: Mon Jun 09, 2003 4:00 am
- Location: Banyoles, Catalonia
- Contact:
Hi Adrian,
Ok. I changed it's status to a bug.
Ok. I changed it's status to a bug.
Best Regards,
Narcís Calvet / Development & Support Steema Software Avinguda Montilivi 33, 17003 Girona, Catalonia Tel: 34 972 218 797 http://www.steema.com |
Instructions - How to post in this forum |
-
- Site Admin
- Posts: 14730
- Joined: Mon Jun 09, 2003 4:00 am
- Location: Banyoles, Catalonia
- Contact:
Hi Adrian,
This defect was assigned a bug-tracking number (TF02012724) before the release of version 3.2.2945.19736. Therefore, if the defect had been fixed for this release then mention of it together with its reference number would have appeared in the release notes. As you can see in the release notes here:
http://www.steema.com/files/public/teec ... elease.txt
No mention of the defect being resolved is made. As a general rule of thumb, and to save you time, one can consider defects which are not stated as resolved in the release notes as still being a problematic issue. In this sense, there is little need for you to check that they are still there.
This defect was assigned a bug-tracking number (TF02012724) before the release of version 3.2.2945.19736. Therefore, if the defect had been fixed for this release then mention of it together with its reference number would have appeared in the release notes. As you can see in the release notes here:
http://www.steema.com/files/public/teec ... elease.txt
No mention of the defect being resolved is made. As a general rule of thumb, and to save you time, one can consider defects which are not stated as resolved in the release notes as still being a problematic issue. In this sense, there is little need for you to check that they are still there.
Best Regards,
Narcís Calvet / Development & Support Steema Software Avinguda Montilivi 33, 17003 Girona, Catalonia Tel: 34 972 218 797 http://www.steema.com |
Instructions - How to post in this forum |