Hi,
I've attached a project which shows that OnClickSeries doesn't fire in certain circumstances in VCL 2010 (I think when the number of viewable points is <2). This may well be an issue related to TV52015075. However, I thought I'd post this project as it highlights not only the incorrect ValueIndex but also OnClickSeries is not called at all in certain circumstances. I cannot find a workaround and it brakes my code so I'd request it is high priority (please!).
Thanks,
Steve
OnClickSeries not firing
-
- Newbie
- Posts: 48
- Joined: Tue Aug 03, 2010 12:00 am
OnClickSeries not firing
- Attachments
-
- ClickableLine2.zip
- (10.16 KiB) Downloaded 463 times
Re: OnClickSeries not firing
Hi Steve,
I don't think it will be related with (TV52015075) because the Cursor is an essential factor to reproduce that problem while the problem in this thread isn't.
I've reproduced the problem with your project and the latest published release, but I'm glad to tell you that I can't reproduce it any more with the actual sources (it would probably have been fixed with TV52015018) so this problem should be fixed with the next maintenance release that should be published in the next weeks.
I don't think it will be related with (TV52015075) because the Cursor is an essential factor to reproduce that problem while the problem in this thread isn't.
I've reproduced the problem with your project and the latest published release, but I'm glad to tell you that I can't reproduce it any more with the actual sources (it would probably have been fixed with TV52015018) so this problem should be fixed with the next maintenance release that should be published in the next weeks.
Best Regards,
Yeray Alonso Development & Support Steema Software Av. Montilivi 33, 17003 Girona, Catalonia (SP) | |