Steema,
Just before a plot displays, I have found one NT machine in our office that displays the message, "The procedure entry point GdiGradientFill could not be located in the dynamic link library GDI32.dll." Other NT and XP machines do not have this problem. The machine where this problem occurs is NOT up to date with Windows Updates. This is intentional so that we can encounter problems like this before they occur in the field. Many of the PCs where this software will reside are in secured facilities with no access to the Internet, so I have to come up with a solution that does not require bringing the PC up to date with the latest Windows Update.
Thank you for any help you can give me with this issue.
Dean Darsey
Entry point GdiGradientFill not located in GDI32.dll
Hi Dean,
you're the first customer with this problem. The only solution that I can think of is update this file on this machine with the one which you've in one of the others NT machines.
you're the first customer with this problem. The only solution that I can think of is update this file on this machine with the one which you've in one of the others NT machines.
Pep Jorge
http://support.steema.com
http://support.steema.com
Entry point GdiGradientFill not located in GDI32.dll
Josep,
Thank you. We'll just have to do that if we are going to expect the same machines to continue to work with evolving packages and operating systems.
Thanks,
Dean Darsey
Thank you. We'll just have to do that if we are going to expect the same machines to continue to work with evolving packages and operating systems.
Thanks,
Dean Darsey